En Es
Categorías

Sun Nuclear

Sun Nuclear

Sun Nuclear, a wholly-owned subsidiary of Mirion Technologies, Inc., provides innovative solutions for Radiation Therapy and Diagnostic Imaging centers. The company’s mission is to enable healthier lives by improving the avoidance, detection and treatment of cancer. More than 5,000 cancer centers worldwide rely on Su ...
Productos Resumen
Close

Sobre Sun Nuclear

Sun Nuclear, a wholly-owned subsidiary of Mirion Technologies, Inc., provides innovative solutions for Radiation Therapy and Diagnostic Imaging centers. The company’s mission is to enable healthier lives by improving the avoidance, detection and treatment of cancer. More than 5,000 cancer centers worldwide rely on Sun Nuclear for independent, integrated Quality Management. With a focus on ongoing support, the company aim to ease technology adoption, enhance workflows and improve outcomes – so that healthcare providers can achieve real results for Patient Safety.

Actualizado

Dose Calibration Electrometer
PC Electrometer

PC Electrometer is an accurate and convenient, dual channel reference class electrometer for absolute dose calibration, available in BNC or TNC triax connectors. Small and lightweight for easy transport, the PC Electrometer offers a simple setup with a single USB cable connection for operation, and less than 1-minute warm-up time.
Mas detalles

Radiation Therapy Treatment Planning Software
PlanIQ

PlanIQ is a radiation therapy software for treatment planning that provides instant feedback on patient-specific treatment plan quality — from the feasibility of achieving established clinical goals to insights on plans can be strengthened. Before treatment planning begins, PlanIQ analyzes the patient-specific feasibility of your clinical goals, with insights on areas for improvement. Target, OAR, and overall plan quality are summarized from “acceptable” to “ideal” for easy identification of weaknesses in the plan.
Mas detalles

Radiation Therapy QA Management Platform
SunCHECK Patient

SunCHECK Patient is a quality management platform for radiation therapy that streamlines data transfer and time-consuming tasks, enabling greater focus on improved treatment quality. In support of standardization, SunCHECK Patient provides common analyses across each Patient QA phase and stores all results for easy retrieval and review.
Mas detalles

Imágenes medicas

Dose Calibration Electrometer
PC Electrometer

PC Electrometer is an accurate and convenient, dual channel reference class electrometer for absolute dose calibration, available in BNC or TNC triax connectors. Small and lightweight for easy transport, the PC Electrometer offers a simple setup with a single USB cable connection for operation, and less than 1-minute warm-up time.
Mas detalles

Radiation Therapy Treatment Planning Software
PlanIQ

PlanIQ is a radiation therapy software for treatment planning that provides instant feedback on patient-specific treatment plan quality — from the feasibility of achieving established clinical goals to insights on plans can be strengthened. Before treatment planning begins, PlanIQ analyzes the patient-specific feasibility of your clinical goals, with insights on areas for improvement. Target, OAR, and overall plan quality are summarized from “acceptable” to “ideal” for easy identification of weaknesses in the plan.
Mas detalles

Radiation Therapy QA Management Platform
SunCHECK Patient

SunCHECK Patient is a quality management platform for radiation therapy that streamlines data transfer and time-consuming tasks, enabling greater focus on improved treatment quality. In support of standardization, SunCHECK Patient provides common analyses across each Patient QA phase and stores all results for easy retrieval and review.
Mas detalles

IMRT Thorax Phantom
CIRS Model 002LFC

The CIRS Model 002LFC IMRT Thorax Phantom for film and ion chamber dosimetry is designed to address the complex issues surrounding the commissioning and comparison of treatment planning systems and complete system QA from CT imaging to dose verification. It is used for more intensive investigations, especially during commissioning, research, and end-to-end testing.
Mas detalles

Mammography Phantom
Mammo 156 Phantom

The Mammo 156 Phantom mimics breast tissue and is a feedback mechanism that provides a framework for constant improvement in early detection and mortality reduction. With this phantom, any technologist (radiographer) on any machine can provide the same image set to help detect breast cancer.
Mas detalles

Motion Control Software
CIRS Motion Control Software Suite

CIRS Motion Control Software Suite is used to operate all CIRS dynamic phantoms and is a user-friendly graphical user interface that can be installed on any computer running Windows OS. Upon installation, the user has the option to select the phantom that is to be controlled by the software. Amplitude, cycle time, and phase shift can be applied to both surrogate and main phantom using slider bars or by entering desired values within the limits of the system.
Mas detalles

Anthropomorphic Torso Phantom
CIRS Model 600

The CIRS Model 600 Anthropomorphic Torso Phantom is designed to simulate an average torso (22 cm anterior-posterior thickness) for training and quality assurance testing in medical imaging and dosimetry. The epoxy materials used to fabricate the phantom provide optimal tissue simulation between the diagnostic and therapy energy range (40 keV to 20 MeV).
Mas detalles

Detector Array
ArcCHECK

ArcCHECK is the only detector array specifically designed to identify errors in rotational delivery. It is the ideal solution for 4D Patient Pre-Treatment QA for IMRT, VMAT, SBRT, and MRgRT; including specialty systems such as Varian Medical Systems Halcyon System and Ethos Therapy; and Accuray TomoTherapy and Radixact Systems.
Mas detalles

Detector
MapCHECK 3

MapCHECK 3 is the gold standard for IMRT QA requiring large field measurements. It offers the highest detector density, highest sensitivity, and largest field size of 2D arrays. Plus, it's uniquely TG 218-compliant.
Mas detalles

Mammography Compliance Phantom
Mammo 156 Phantom

The FFDM Phantom, 156 Phantom, 156D Stereo Phantom, and 3D Performance Kit ensure both quality and compliance for digital mammography systems. The mammo compliance phantoms simulate the radiographic characteristics of compressed breast tissue, including micro-calcifications, ductal fibrous structures and tumor-like masses.
Mas detalles

Doppler Ultrasound Phantoms
Doppler 403 /Mini-Doppler 1430

Doppler 403 and Mini-Doppler 1430 flow phantoms help assess system velocities using precision flow rates and proprietary blood-mimicking fluid. Designed to verify ultrasound system and transducer performance, both phantoms are self-contained Doppler flow and B-Mode QA test systems, with streamlined fluid flow at variable rates in a continuous or pulsed mode.
Mas detalles

CT Image Quality Phantom
IQphan

IQphan is a comprehensive CT image quality phantom that addresses QA across the range of specifications of different CT scanners, enabling you to gain more QA information. With IQphan, users can perform QA across CT imaging systems, from sophisticated diagnostic scanners to cone beam to on-board radiotherapy systems, and a combination of modules supports a robust variety of tests.
Mas detalles

Ultrasound Phantom
Multi-Purpose Multi-Tissue Ultrasound Phantom - Model 040GSE

The CIRS Model 040GSE Multi-Purpose, Multi-Tissue Ultrasound Phantom is the most complete solution available for performance and quality assurance testing. Its dual frequency design and detachable water wells allow testing of most transducer shapes – including curvilinear and endocavity – and frequencies. It is also the only QA phantom on the market that provides both elasticity targets and all the standard B-mode imaging test objects.
Mas detalles

Family Phantom Models
ATOM Phantom Family - Model 701-706

The ATOM family consists of six clinically relevant ages including, a newborn, 1-year old, 5-year old, 10-year old, adult male, and adult female, with each phantom age accounting for key variations in tissue composition due to age or sex and accounts for variations in bone mineral density. This results in a more precise physical model with which to investigate the interaction of radiation with different tissues and also allows for more accurate dose calculations in different age groups.
Mas detalles

IMRT Head and Neck Phantom
IMRT Phantom Model 002HN

The CIRS Model 002HN IMRT Phantom is designed to address the complex issues surrounding commissioning and comparison of treatment planning systems and complete system QA from CT imaging to dose verification. The CIRS 002HN phantom properly represents human head and neck anatomy in shape, proportion and structure as well as density, enabling thorough analysis of both the treatment planning and delivery systems.
Mas detalles

Shoulder, Head and Neck End-to-End Verification Phantom
Phantom Patient for VMAT & IMR - Model 136500

The CIRS Shoulder, Head and Neck End-to-End Verification Phantom (SHANE) is designed for end-to-end testing of treatment planning systems. The phantom can be used for every step in this process from imaging acquisition to dosimetry verification and patient-specific QA during head-and-neck VMAT and IMRT procedures.
Mas detalles

SBRT Phantom with Removable Spine
E2E SBRT Phantom with Removable Spine Model 036S-CVXX-xx

E2E SBRT Phantom with Removable Spine Model 036S-CVXX-xx is an anthropomorphic thorax body containing articulated spine, ribs, and lungs and provides a means to check the entire treatment chain during commissioning and routine QA. It has more options for dose verification in the spine as an organ at risk, including a removable split spine, to facilitate the use of radiochromic film in the sagittal orientation in the inferior half of the spine rod.
Mas detalles

Proton Therapy Dosimetry Head Phantom
Proton Therapy Dosimetry Head Model 731-HN

The CIRS Proton Therapy Dosimetry Head is an anthropomorphic head phantom designed for commissioning and treatment planning system (TPS) verification with any conformal or IMRT Proton Therapy system. The phantom is constructed of CIRS tissue-equivalent materials, which mimic reference tissues within 1.5% for protons and within 1% for photons from 50 KeV to 15 MeV.
Mas detalles

Stereotactic End-to-End Verification Phantom (STEEV)
Phantom Patient for Stereotactic End-to-End Verification Model 038

The CIRS Stereotactic End-to-End Verification Phantom (STEEV) provides a means to check all necessary steps of a treatment planning system - from diagnostic imaging with CT, MR and PET, to treatment plan verification. It accommodates five interchangeable multi-modality inserts which come with a variety of internal targets and must be filled with MRI or PET compatible liquids.
Mas detalles

Head & Torso Phantom
IMRT Head & Torso Freepoint Phantom Model 002H9K

The IMRT Head & Torso Freepoint Phantom Model 002H9K simulates the patient through the entire process from CT data acquisition and planning to delivery and dose verification. Constructed of proprietary tissue equivalent epoxy materials, these unique materials eliminate the need for correction factors, thus improving accuracy and saving time.
Mas detalles

Lung Tracking Phantom
XSight Lung Tracking Phantom Kit Model 18023-A

Xsight Lung Tracking Phantom body represents an average human thorax in shape, proportion and composition and includes a single dosimeter rod made from lung equivalent epoxy (of respective densities). It has been verified and validated by Accuray for use with CyberKnife systems and both are designed to work in conjunction with the Synchrony System.
Mas detalles

Thorax Motion Phantom
Dynamic Thorax Phantom Model 008A

The CIRS Dynamic Thorax Motion Phantom is a precision instrument for investigating and minimizing the impact of tumor motion inside the lung. It provides known, accurate and repeatable three-dimensional target motion inside a tissue-equivalent phantom. It is designed for comprehensive analysis of image acquisition, planning and dose delivery in image-guided radiation therapy.
Mas detalles

Laser Alignment Solutions
CT SIM+ & MICRO+

The CT SIM+ & MICRO+ Laser Alignment solutions offer accuracy, stability and durability in a busy clinical environment. The CT SIM+ moveable laser system is designed from the ground up to support PET/CT Simulation workflow while the MICRO+ lasers support fixed patient alignment for radiation therapy and diagnostic imaging.
Mas detalles

Radiation Therapy QA Software
SunCHECK

The SunCHECK software platform enables centralized and standardized Radiation Therapy Quality Management among staff, sites and equipment. The integrated, independent Patient and Machine QA provides standardization and workflow efficiency with independent QA removing bias to ensure more treatment and machine issues will be caught.
Mas detalles

Radiosurgery/Radiation Therapy QA Software
SRS MapCHECK

SRS MapCHECK supports the prevention of treatment errors for a broad range of stereotactic radiosurgery and radiation therapy delivery systems - from conventional C-arm linacs to Accuray's CyberKnife System. It removes film and subjectivity from SRS/SBRT QA, offering streamlined, digital testing for improved Patient Safety, making it a consistent, easy-to-maintain method for high-density absolute dose measurements.
Mas detalles

Motion Management QA Phantom
Zeus MRgRT Motion Management QA Phantom

The CIRS Zeus MRgRT Motion Management QA phantom is designed to address the integration of MR imaging in radiation therapy for facilitating real-time motion management. Zeus is MR Safe due to the use of piezoelectric motors and non-ferromagnetic materials, and is designed as a single unit with a piezo actuator fixed permanently to a base plate on which the MRI body “snaps”. CIRS Motion Control software drives this phantom as well as the other phantoms from the CIRS dynamic family.
Mas detalles

Pediatric Radiography Training Phantom
SPoRT Sectional Pediatric Radiography Trainer

The SPoRT Sectional Pediatric Radiography Trainer is an ideal addition to any imaging department or Radiologic Technology training program, and can assist in the monitoring, training and improvement of parameters and protocols common to most pediatric imaging procedures. It is designed to aid teaching and improvement of patient positioning, collimation and anatomical comprehension and it’s wide range of features facilitate effective instruction of safe, high quality, pediatric imaging. SPoRT can be used in film radiography, CR, DR and Computed Tomography.
Mas detalles

Phantom Patient for VMAT & IMRT
SHANE

The CIRS Shoulder, Head and Neck End-to-End Verification Phantom (SHANE) is designed for end-to-end testing of treatment planning systems and can be used for every step in this process from imaging acquisition to dosimetry verification and patient-specific QA during head- and-neck VMAT and IMRT procedures. The high-fidelity anthropomorphic design contains complex internal anatomy that provides a realistic clinical simulation to evaluate the challenging effects of intra- and extracranial anatomies.
Mas detalles

Doppler Flow Pump
Model 769

The new improved Model 769 Doppler Flow Pump, is compatible with both its ATS Urethane flow phantoms as well as its new Model 069A Zerdine flow phantom and provides a complete solution for QA testing of Doppler ultrasound devices.
Mas detalles

Abdominal Phantom
Triple Modality 3D Abdominal Phantom

The CIRS Model 057A Triple Modality 3D Abdominal Phantom is constructed of a self-healing formulation of Zerdine 1 that allows multiple biopsy insertions with minimal needle tracking, and is ideal for demonstrating image-guided navigation technologies. It can be imaged under CT, MR and ultrasound, making it a useful tool for applications such as image fusion studies; imaging protocol developments; scan technique training; and system testing, validation and demonstration.
Mas detalles

Multi-Modality Male Pelvic Phantom
Multi-Modality Male Pelvic Phantom

The Model 048A Multi-Modality Male Pelvic Phantom is designed for realistic abdominal and transrectal ultrasound scanning of the bladder and prostate. It includes pelvic bones, anechoic bladder, prostate, urethra, seminal vesicles and rectum enclosed in a pelvic-shaped plastic housing with a Z-SkinTM membrane.
Mas detalles

Breast Imaging Phantom
BR3D Breast Imaging Phantom

The CIRS Model 020 BR3D Breast Imaging Phantom assesses detectability of lesions of various sizes within a tissue equivalent, heterogeneous background. It contains six heterogeneous, breast-equivalent slabs, which accurately demonstrate how underlying targets can be obscured by varying glandularity.
Mas detalles

FANTASMA DE ULTRASONIDO
Model 054GS

El Modelo 054GS contiene objetivos de escala de grises y objetivos de sensibilidad mejorados que exceden los requisitos del programa de acreditación de la ACR. Proporciona propiedades de imitación de tejidos y es compatible con imágenes armónicas.
Mas detalles

SOFTWARE DE CONTROL DE CALIDAD
Ultrasound Quality Assurance Portal

El Portal de Garantía de Calidad ayuda a los usuarios a administrar su programa de pruebas de ultrasonido con una aplicación fácil de usar, basada en la nube. El software proporciona informes/gráficos para rastrear resultados y viene con protocolos de prueba predeterminados.
Mas detalles

Phantom
SRS Multi-Lesion Brain QA Phantom

The SRS Multi-Lesion Brain QA Phantom provides a unique solution for fast, comprehensive film dosimetry for single isocenter plans treating multiple targets simultaneously. It can be used for thorough validation of multi-lesion treatment methods and for patient-specific quality assurance.
Mas detalles

Phantom
Dynamic Cardiac Phantom

The Dynamic Cardiac Phantom is a precision instrument that simulates the realistic motion of an average human heart by providing known, accurate and repeatable 3D motion of a solid heart model inside the tissue-equivalent thorax phantom. It is designed as a comprehensive image analysis tool for calcification detection, iodine contrast resolution and ECG signal gating.
Mas detalles

MRI Distortion Phantom
Model 604

The Model 604 is a large field MRI distortion phantom designed for the assessment of MRI distortion caused mainly by the non-linearity of magnetic gradients. It can also help quantify MRI image distortion due to chemical shifts and susceptibility owing to density differences common in diagnostic and RT treatment planning.
Mas detalles

Digital Breast Tomosynthesis QC Phantom
Model 021

The Model 021 digital breast tomosynthesis QC phantom is designed to address quality control for digital breast tomosynthesis systems and can be used for software analysis and “traditional” visual tests. It consists of eight homogeneous slabs made from breast-equivalent material in 50/50 ratio of gland and adipose tissue (BR50/50) and includes a positioning holder with magnetic fixation for repeatable alignment and positioning on the DBT scanner.
Mas detalles

Fantasma Mamografia
Model 086

El modelo 086 ACR ensaya los sistemas FFDM para ver si pueden detectar pequeñas estructuras, que son importantes en la detección temprana del cáncer de mama. Permite a los revisores ver las puntuaciones y los artefactos en imágenes individuales sin la necesidad de diferentes configuraciones.
Mas detalles

Cirugía

FANTASMA ENDOSCOPICO
Model ATS 570

El modelo ATS 570 evalúa los sistemas de imágenes en la mayoría de las frecuencias de imágenes clínicas. Ofrece objetivos de línea de monofilamento para mediciones de distancia y tejidos que imitan estructuras diana de diferentes tamaños y contrastes.
Mas detalles
Derecho de autor © 2000-2024 TradeMed.com. Todos los derechos reservados. | Términos y condiciones